Model:MQ-KM1
Thermal Vacuum Chambers
Technical indicators
product name |
Space environment simulation test equipment |
||
Product model |
MQ-KM1 |
MQ-KM2 |
MQ-KM3 |
Vacuum chamber size |
φ1000X1500mm |
φ2000×2500mm |
φ3000×3500mm |
Ultimate vacuum |
≤5×10-5Pa |
||
Working vacuum |
≤1.0×10-3Pa |
||
Refrigeration method |
Coolant method |
Compound working method |
Liquid nitrogen refrigeration |
Heat sink + cold plate |
Heat sink + heating cage |
Liquid nitrogen heat sink + heating cage |
|
Temperature range |
-75℃~+130℃ |
-110℃~+150℃ |
-173℃~+170℃ |
Temperature stability |
≤1℃/h |
≤1℃/h |
≤1℃/h |
Temperature uniformity |
≤±2.0℃ |
≤±3.0℃ |
≤±5.0℃ |
Temperature control accuracy |
±1℃ |
±1℃ |
±1℃ |
Heating rate |
≥1℃/Min |
||
Vacuum system leakage rate |
<5×10-9 Pa.m3/s |
||
Noise |
Vacuum pumping equipment noise <70dB |
||
Vacuum time |
The container can be pumped to better than 1.0×10 -3 Pa within 4 hours under no-load conditions at normal temperature |
||
Temperature detection system |
The system uses multi-channel Pt100 temperature inspection meter to measure multi-point temperature |
||
Control monitoring system |
Mainly includes industrial control computers, control cabinets, PLCs, instruments, various operation control switches, etc. |
||
Controller |
Siemens PLC, communication module, communication cable |
||
Voltage |
380±10% VAC, 3L+N+G |
||
Standard configuration |
Sample platform 1 set, 1 manual |
||
safety devices |
Phase sequence protection, leakage protection, reliable grounding, emergency power off button, over voltage, over current, over temperature alarm and protection control |
||
Environmental requirements |
Ambient temperature: 5 ~ 35 °C, relative humidity: ≤ 40% RH, no strong vibration, electromagnetic radiation, no dust and corrosive substances around; |
||
Note: 1. The performance parameters are in the ambient temperature of 25 °C, vacuum chamber no-load test; 2.according to the specific requirements of the user non-standard custom; 3. This technical information is subject to change without notice. |
Standard Compliance :
GJB 1027A: Carrier, Upper Stage, and Spacecraft Test Requirements
GJB 1033: Satellite Thermal Balance Test Method
QJ 1446A: Satellite Thermal Balance Test Method
QJ 2630.1: Satellite Component Space Environmental Test Method - Thermal
Vacuum Test
QJ 2630.2: Satellite Component Space Environmental Test Method - Thermal Balance Test
QJ 2630.3: Satellite Component Space Environment Test Method - Vacuum Discharge Test
GB 150-1998: Steel Pressure Vessels
GB/T 3164-2007: Graphical Symbols for Vacuum Technology System Diagrams
GB/T 6070-2007: Vacuum flange
GB 50054-1995: Low Voltage Distribution Design Specification
GB 50316-2008: Industrial metal pipeline design specification