Thermal Vacuum Chambers
Space environment simulation Thermal Vacuum Chamber has a high degree of automation, precise temperature control, simple and convenient operation, stable and reliable long-term operation; The coolant temperature adjustment stage realizes the coexistence of radiation and heat conduction in a vacuum environment, and increases the temperature rise and fall of the specimen. Use cryogenic pumps and dry pumping systems to eliminate oil contamination from the vacuum system;

Model:MQ-KM1

Update time:[2019-10-31]
Feature Parameter Standard Compliance

Thermal Vacuum Chambers 

 

Technical indicators

product name

Space environment simulation test equipment

Product model

MQ-KM1

MQ-KM2

MQ-KM3

Vacuum chamber size

φ1000X1500mm

φ2000×2500mm

φ3000×3500mm

Ultimate vacuum

≤5×10-5Pa

Working vacuum

≤1.0×10-3Pa

Refrigeration method

Coolant method

Compound working method

Liquid nitrogen refrigeration

Heat sink + cold plate

Heat sink + heating cage

Liquid nitrogen heat sink + heating cage

Temperature range

-75℃~+130℃

-110℃~+150℃

-173℃~+170℃

Temperature stability

≤1℃/h

≤1℃/h

≤1℃/h

Temperature uniformity

≤±2.0℃

≤±3.0℃

≤±5.0℃

Temperature control accuracy

±1℃

±1℃

±1℃

Heating rate

≥1℃/Min

Vacuum system leakage rate

<5×10-9 Pa.m3/s

Noise

Vacuum pumping equipment noise <70dB

Vacuum time

The container can be pumped to better than 1.0×10 -3 Pa within 4 hours under no-load conditions at normal temperature

Temperature detection system

The system uses multi-channel Pt100 temperature inspection meter to measure multi-point temperature

Control monitoring system

Mainly includes industrial control computers, control cabinets, PLCs, instruments, various operation control switches, etc.

Controller

Siemens PLC, communication module, communication cable

Voltage

380±10% VAC, 3L+N+G

Standard configuration

Sample platform 1 set, 1 manual

safety devices

Phase sequence protection, leakage protection, reliable grounding, emergency power off button, over voltage, over current, over temperature alarm and protection control

Environmental requirements

Ambient temperature: 5 ~ 35 °C, relative humidity: ≤ 40% RH, no strong vibration, electromagnetic radiation, no dust and corrosive substances around;

Note:

1. The performance parameters are in the ambient temperature of 25 °C, vacuum chamber no-load test;

2.according to the specific requirements of the user non-standard custom;

3. This technical information is subject to change without notice.

 

Standard Compliance :

GJB 1027A: Carrier, Upper Stage, and Spacecraft Test Requirements
GJB 1033: Satellite Thermal Balance Test Method
QJ 1446A: Satellite Thermal Balance Test Method
QJ 2630.1: Satellite Component Space Environmental Test Method - Thermal
Vacuum Test
QJ 2630.2: Satellite Component Space Environmental Test Method - Thermal Balance Test
QJ 2630.3: Satellite Component Space Environment Test Method - Vacuum Discharge Test
GB 150-1998: Steel Pressure Vessels
GB/T 3164-2007: Graphical Symbols for Vacuum Technology System Diagrams
GB/T 6070-2007: Vacuum flange
GB 50054-1995: Low Voltage Distribution Design Specification
GB 50316-2008: Industrial metal pipeline design specification
 

 

Related products
Products
Relevant news

skype:christine.wang268

phnoe:+86 17319082380

email:zhongkemeiqi@zkmeiqi.com

whatsapp:+86 17319082380