Model:MQ-THV1000
Temperature HUmidity Vibration Test Chamber
Temperature Humidity Vibration Test Chamber
Technical indicators
Product name |
Temperature and humidity vibration three comprehensive test chamber |
|||
Product model |
MQ-THV500 |
MQ-THV1000 |
MQ-THV2000 |
|
Nominal volume |
Unit/L |
500 |
1000 |
2000 |
Inner size |
Width × depth × height (mm) |
750×750×900 |
1000×1000×1000 |
1300×1300×1200 |
External size |
Width × depth × height (mm) |
950×2400×1950 |
1200×2600×2150 |
1500×3500×2400 |
Performance index |
temperature range |
A,-40℃~150℃ B,-70℃~150℃ C,-90℃~150℃ |
||
Humidity range |
A,10%~98%RH B,20%~98%RH C, 30%~98%RH |
|||
Temperature fluctuation |
±0.5℃ |
|||
Humidity fluctuation |
≤±2%RH |
|||
Temperature uniformity |
≤±2.0℃ |
|||
Temperature deviation |
≤±2.0℃ |
|||
Humidity deviation |
Humidity>75%RH:≤+2,-3%RH; Humidity<75%RH:≤±5%RH |
|||
Heating rate |
2,5,10,15,20℃/ Min |
|||
Cooling rate |
2,5,10,15,20℃/ Min |
|||
Vibration frequency |
3~2500HZ;3~3000HZ;5~4500HZ; |
|||
Maximum acceleration |
500m/s2;700 m/s2;1000m/s2; |
|||
Maximum displacement |
25mm;51mm; |
|||
Table size |
φ320mm;φ445mm;φ550mm; |
|||
Refrigeration method |
Compressor refrigeration |
|||
Cooling method |
Air-cooled/water-cooled |
|||
Main components
|
Control System |
Siemens programmable controller + touch screen + independent development program |
||
Heating system |
Fully independent system, high efficiency stainless steel finned tube heater |
|||
Cooling System |
Importer-type scroll compressor |
|||
Circulatory system |
Temperature and low noise motor, stainless steel centrifugal impeller |
|||
Main materials |
Carton material |
High-quality carbon steel plate, phosphating electrostatic spray treatment |
||
Inner box material |
International standard SUS304# stainless steel mirror treatment |
|||
Insulation material |
Hard flame retardant polyurethane foam |
|||
Sealing material |
High and low temperature environment-friendly silicone rubber seal |
|||
Voltage |
380±10% VAC, 50Hz; 3L+N+G |
|||
Communication Interface |
RS232 communication interface, USB data interface |
|||
Standard configuration |
1 sample holder, 1 test lead hole, 1 movable bottom plate, 1 sealed bottom plate |
|||
Optional accessories |
Recorder, remote control software, insulated sample holder, split operator, dry air purge, |
|||
Safety devices |
Leakage, short circuit, motor overheating, heater overheating, humidification, water shortage, compressor overpressure, overload, multiple overtemperature protection |
|||
Environmental requirements |
Ambient temperature: 5 ~ 35 °C, relative humidity: ≤ 85% RH, no strong vibration, electromagnetic radiation, dust and corrosive substances around; |
|||
Note: 1.temperature performance parameters are in the ambient temperature of 25 °C, studio no load conditions, in accordance with GB/T5170.2-2008 test; 2. can be customized according to the specific requirements of the user non-standard three comprehensive high and low temperature test chamber; 3. This technical information is subject to change without notice. |
Standard Compliance :
1.GB/T 10589-2008 :cryogenic test chamber technical conditions
2.GB/T 10592-2008 :high and low temperature test chamber technical conditions
3. IEC60068-2-1 Environmental testing - Part 2: Test methods - Tests A: Cold
4. IEC60068-2-2 Environmental testing for electric and electronic products Test methods - Tests B: Dry Heat
5. IEC60068-2-78 Environmental testing - Part 2-78: Tests -Test Cab: Damp heat ,steady state
6. IEC60068-2-30 Environmental testing for electric and electronic products - Part 2: Test method - Test Db: Damp heat, cyclic (12h+12h cycle)
7. IEC60068-2-14 Environmental testing for electric and electronic products-Part 2: Test Methods-Test N: Change of temperature
8. MIL-STD-810F-501.4 High temperature test
9. MIL-STD-810F-502.4 Low temperature test
10. MIL-STD-810F-507.4 Damp heat test
11.GJB 360B-2009: test methods for electronic and electrical components
12.JJF 1270-2010: calibration specification for temperature, humidity and vibration integrated environmental testing system
13.GB/T 5170.2-2008: test method for environmental test equipment of electric and electronic products Temperature test equipment